Sign In | Join Free | My burrillandco.com
burrillandco.com

Qingdao AIP Intelligent Instrument Co., Ltd

Qingdao AIP Intelligent Instrument Co., Ltd Customer - Oriented, Striver - First

Site Member

8 Years

Home > Safety Testing System >

2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances

Qingdao AIP Intelligent Instrument Co., Ltd
Contact Now
    Buy cheap 2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances from wholesalers
     
    Buy cheap 2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances from wholesalers
    • Buy cheap 2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances from wholesalers
    • Buy cheap 2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances from wholesalers
    • Buy cheap 2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances from wholesalers

    2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances

    Ask Lasest Price
    Brand Name : AIP
    Model Number : AIP965* series
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 50 Sets per month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    2KV / 5KV Electrical Safety Analyzer High Precision For Home Appliances

    Electrical Safety Testing System/Safety Analyzer/Tester For Home Appliances


    1. Product features

    Meet requirements in CCC, IEC, EN, VDE, BS, GS, UL and other general electrical safety specifications. Optional equipped IPC, automatic control and data entry with optional barcode scanners, to build production data management platform which can be integrated into the production management system. Up to 100 sets of testing conditions can be memorized. With 8 testing steps, each set’s specification model can be set individually for quick search. High precision: up to 3%. Hi-pot voltage is featured with ramp up/down setting, max./min. alarm. Voltage and resistance judgment modes can be selected for grounding resistance test items, so as to meet the standard requirements of different countries and industries.


    2. Test: leakage current, no-load power, low-voltage start up, AC Hipot, insulation resistance, grounding resistance


    3. Parameters specification

    Leakage current
    Output voltage1.06 times rated voltage, built-in variable frequency inverter
    Leakage type settingDynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely.
    Output voltage setting range/precisionAC 50~280V ±(0.5%×display value+2 words)
    Leakage current setting range/precision0.05~20.00mA ±(1.5%×display value+10uA)
    Leakage current setting alarm rangeMax.: 0.05~20.00mA; Min.: 0.01~5.00mA
    Test time range/resolution1~300s 1s/step
    No-load power
    Output voltage1.0 times rated voltage, built-in variable frequency inverter
    Output voltage measurement range/precisionAC 50~280V ±(0.2%×display value+0.05%×measuring range)
    Output current measurement range/precisionAC 0.20~30.00A ±(0.2%×display value+0.05%×measuring range)
    Active power measurement range/precision30~6000W ±(0.2%×display value+0.05%×measuring range)
    Power setting alarm rangeMax.: 3~6000W ; Min.: 0~6000W
    Test time range/resolution1~300s 1s/step
    Low voltage start-up
    Output voltage0.85 times rated voltage, built-in variable frequency power
    Output voltage measurement range/precisionAC 50~280V ±(0.5%×display value+2 words)
    Start-up current measurement range/precisionAC 0.20~30.00A ±(0.5%×display value+2 words)
    Current setting alarm rangeMax.: 0.20~30.00A ; Min.: 0.00~25.00A
    Test time range1~300s 1s/step
    AC Hi-pot
    Output voltage setting range/precisionAC 200~5000V ±(1.5%×setting value+5 words) static
    Breakdown current measurement range/precision0.10~99.99mA ±(1.5%×display value+5 words)
    Breakdown current preset alarmMax.: 0.10~99.99mA; Min.: 0.00~5.00mA
    Test time range/resolution1~300s 1s/step
    Arc detection(optional)1~9 level(9 is the most sensitive level)
    Insulation resistance
    Output voltage setting range/precisionDC 200~1000V ±(3%×reading+5 words)
    Insulation resistance measurement range/precision1~2000MΩ ≤100MΩ:±(5%×display value+3 words) >100 MΩ:±(8%×display value+8 words)
    Insulation resistance alarm setting rangeMax.: 0~2000MΩ; Min.: 1~2000MΩ
    Test time range/resolution1~300s 1s/step
    Grounding resistance
    Grounding current output range/precisionAC 5.0~30.0A ±(1.5%×setting value+0.2A)
    Grounding resistance measurement range/precision10.0~600mΩ ±(1.5%×display value+3mΩ)
    Grounding resistance alarm setting rangeMax.: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;
    Min.: 0.0~100mΩ