| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | AIP | 
| Model Number : | AIP89XX | 
| Price : | Negotiable | 
| Payment Terms : | L/C, T/T | 
| Supply Ability : | 50 sets per month | 
| Delivery Time : | 45 working days | 
Electric Motor Testing Machine For Milling Machine, Automatic Motor Test
1. Test product: motor of milling machine, powder milling machine.
2. Application industry: home appliance tools
3. Test: surge, winding resistance, insulation resistance, Hipot, Low-voltage start, no-load power
4. Technical parameters:
4.1 Surge
| output voltage setting range/precision | 500~3000V ±(3%×setting value+8V) | 
| sampling frequency | 100MHz | 
| waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface | 
4.2 DC Winding resistance :
| testing range and precision | 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set. | 
| test time range/resolution | 0.5~20s 0.1s/step | 
| temperature compensation function | Yes | 
| temperature probe/range | DS18b20 -10.0℃~+50.0℃ | 
| precision | ±0.5°C(range: -10℃~+50℃) | 
4.3 Insulation Resistance:
| output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) | 
| insulation resistance testing range/precision | 1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ) | 
| insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ | 
| test time range/resolution | 0.5~999s 0.1s/step | 
4.4 AC Hipot:
| Output voltage setting range and precision | AC 500~3000V ±(2%×setting value+10V) | 
| breakdown current testing range/precision | 0.10~20.00mA ±(2%×setting value+0.05 mA) | 
| Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA | 
| Hipot current/resolution | ±(2% display value+0.05 mA);0.01 mA | 
| test time range/resolution | 0.5~999.9s 0.1s/step | 
| Arc detection | 0~9 level | 
4.5 Low voltage start:
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) | 
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) | 
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) | 
4.6 No-load:
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) | 
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) | 
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) | 
5. Configuration
| No. | Name | Specification | Unit | 
| 1 | Master unit | Customized | Set | 
| 2 | Test bench | Customized clamps | Set | 
| 3 | Test software | Save the test requirements, data and control the test process | Set | 
| 4 | Cabinet | Easy to be moved with foot wheels | Set | 
|   | 
 
                                 
                                 
                                 
                                