Qingdao AIP Intelligent Instrument Co., Ltd
Contact Now
    Buy cheap Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines from wholesalers
     
    Buy cheap Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines from wholesalers
    • Buy cheap Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines from wholesalers
    • Buy cheap Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines from wholesalers
    • Buy cheap Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines from wholesalers

    Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines

    Ask Lasest Price
    Brand Name : AIP
    Model Number : AIP89XX
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 50 sets per month
    Delivery Time : 45 work days
    • Product Details
    • Company Profile

    Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines

    Safety Testing System / Electrical Safety Testing System for Fan


    1. Features:

    • Suit for production lines of air fan, ceiling fan, floor fan etc.
    • Optionally equipped with industrial computer to accomplish automatic control and data recording with a barcode scanner device, and to build a platform of managing production data, and the platform support communication with the production management system.
    • Optionally equipped with inverter power source to achieve automatic testing and the keep the stability of the output voltage. It has no effect on output results.
    • Storage space of test items and results is unlimited, maximum 8 test procedures for each testing group, each test group can be established with a type name. Type querying is available.
    • Test items can be selected or hidden as per your requirement.
    • Several test items could be finished in one-time testing with high efficiency.
    • Small and easy to move.

    2. Technical parameters:

    AC Hipot

    Output voltage setting range/precision

    AC 200~5000V ±(3%*setting value + 5 digit)

    Breakdown current measuring range/precision

    0.10~99.99mA ±(3%*displayed value + 5 digit)

    Presetting breakdown current alarm range/precision

    Up limit: 0.10~99.99mA;

    Lower limit: 0.00~5.00mA

    Testing time range/resolution

    1~300S 1s/step

    Insulation resistance

    Output voltage setting range/precision

    DC 500/1000V ±(3%*displayed value + 5 digit)

    Insulation resistance measuring range/precision

    1~2000MΩ Within 100MΩ: ±(5%*displayed value + 3 digit);

    Above 100MΩ: ±(8%*displayed value + 8 digit);

    Presetting insulation resistance alarm range/precision

    Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ

    Testing time range/resolution

    1-300s 1s/step

    Grounding

    Ground current output range/precision

    AC 5.0~30.0A ±(3%*setting value + 5 digit)

    Ground resistance measuring range/precision

    10.0~600mΩ±(3%*displayed value + 5 digit)

    Presetting ground resistance alarm range

    Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ

    Lower limit: 0.0 ~100mΩ

    Testing time/resolution

    1~60s 1s/step

    Leakage current

    Output voltage

    1.06 times of nominal voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Leakage current measuring range/precision

    0.05~20.00mA ±(3%*displayed value +0.02mA)

    Presetting leakage current alarm range

    Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA

    Testing time range/resolution

    1~300s 1s/step

    power

    Output voltage

    Equals input voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Output current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Power measuring range/precision

    30~6000W ±(0.5%*displayed value + 5 digit)

    Presetting power alarm range

    Up limit: 30~6000W; Lower limit: 0~6000W

    Testing time/resolution

    1~300s 1s/step

    Low voltage starts

    Output voltage

    O.85 times of input voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Starting current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Presetting current alarm range

    Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A

    Testing time/resolution

    1~300s 1s/step


    3. About electrical safety testing:

    • Common 4 test items of electrical safety testing are insulation resistance, AC Hipot, leakage current and ground resistance.
    • Dielectric strength test also has been called AC Hipot,which is applying several times of rated voltage to the tested object between changed components and product case, and to test if there is a breakdown current or the charged component has been grounded.
    • The leakage current is the current that pass the insulation part and flow into the grounding conductive wire when the tested product is applied testing voltage.
    • Earth-continuity is the connecting resistance between accessible mental part of tested object and ground lead, it’s different from protective ground resistance.

    4. Image of tested object:


    5. Image of electrical safety testing system


    Quality Safety High Voltage Test Equipment For Air / Ceiling Fan Production Lines for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Qingdao AIP Intelligent Instrument Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)