| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | AIP | 
| Model Number : | AIP89XX | 
| Price : | negotiation | 
| Payment Terms : | L/C, T/T | 
| Supply Ability : | 50 sets per month | 
| Delivery Time : | 45 work days | 
Safety Testing System / Cabinet Type Electrical Safety Testing
System
1. Features:
2. Technical parameters:
| AC Hipot | |
| Output voltage setting range/precision | AC 200~5000V ±(1.5%*setting value + 5 digit) | 
| Breakdown current measuring range/precision | 0.10~99.99mA ±(1.5%*displayed value + 5 digit) | 
| Presetting breakdown current alarm range/precision | Up limit: 0.10~99.99mA; | 
| Testing time range/resolution | 1~300S 1s/step | 
| DC withstand voltage | |
| Output voltage setting range/precision | DC 200~5000V ±(1.5%*setting value + 5 digit) | 
| Breakdown current measuring range/precision | 0.10~10.00mA ±(1.5%*displayed value + 5 digit) | 
| Presetting breakdown current alarm range/precision | Up limit: 0.10~10.00mA; | 
| Testing time range/resolution | 1~300S 1s/step | 
| Insulation resistance | |
| Output voltage setting range/precision | DC 500/1000V ±(1.5%*displayed value + 5 digit) | 
| Insulation resistance measuring range/precision | 1~2000MΩ Within 100MΩ:±(5%*displayed value + 3 digit); | 
| Presetting insulation resistance alarm range/precision | Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ | 
| Testing time range/resolution | 1-300s 1s/step | 
| Grounding | |
| Ground current output range/precision | AC 5.0~30.0A ±(1.5%*setting value + 5 digit) | 
| Ground resistance measuring range/precision | 10.0~600mΩ±(1.5%*displayed value + 5 digit) | 
| Presetting ground resistance alarm range | Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ | 
| Testing time/resolution | 1~60s 1s/step | 
| Leakage current | |
| Output voltage | 1.06 times of nominal voltage | 
| Setting of leakage type | Dynamic leakage, static leakage, built-in body impedance network is optional, customized is available. | 
| Output voltage measuring range/precision | AC 50~280V ±(0.5%*displayed value + 2 digit) | 
| Leakage current measuring range/precision | 0.05~20.00mA ±(1.5%*displayed value +0.02mA) | 
| Presetting leakage current alarm range | Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA | 
| Testing time range/resolution | 1~300s 1s/step | 
| power | |
| Output voltage | Equals input voltage | 
| Output voltage measuring range/precision | AC 50~500V ±(0.5%*displayed value + 2 digit) | 
| Output current measuring range/precision | AC 0.20~40.00A ±(0.5%*displayed value + 2 digit) | 
| Power measuring range/precision | 30~20000W ±(0.5%*displayed value + 5 digit) | 
| Presetting power alarm range | Up limit: 30~20000W; Lower limit: 0~20000W | 
| Testing time/resolution | 1~300s 1s/step | 
| Low voltage start | |
| Output voltage | O.85 times of input voltage | 
| Output voltage measuring range/precision | AC 50~500V ±(0.5%*displayed value + 2 digit) | 
| Starting current measuring range/precision | AC 0.20~40.00A ±(0.5%*displayed value + 2 digit) | 
| Presetting current alarm range | Up limit: 0.20~40.00A; Lower limit: 0.00~25.00A | 
| Testing time/resolution | 1~300s 1s/step | 
Accessories: power cord*1, foot switch*1(30A), clamp*2, test box1,
input power wire*1, fuse tube*1.
3. Tips of AC Hipot:

|   | 
 
                                 
                                 
                                 
                                